59 of 59 documented models · Source PDF pp. 8–9
| Model | Displacement ml/rev | Reference flow m³/day at 100 rpm¹ | Stages | Water head² m | Shortlist |
|---|---|---|---|---|---|
| GLB28-18 | 28 | 4 | 18 | 800 | |
| GLB28-27 | 28 | 4 | 27 | 1,200 | |
| GLB28-40 | 28 | 4 | 40 | 1,800 | |
| GLB28-55 | 28 | 4 | 55 | 2,500 | |
| GLB40-21 | 40 | 5.8 | 21 | 950 | |
| GLB40-27 | 40 | 5.8 | 27 | 1,200 | |
| GLB40-45 | 40 | 5.8 | 45 | 2,000 | |
| GLB75-21 | 75 | 10.8 | 21 | 950 | |
| GLB75-27 | 75 | 10.8 | 27 | 1,200 | |
| GLB75-40 | 75 | 10.8 | 40 | 1,800 | |
| GLB75-50 | 75 | 10.8 | 50 | 2,250 | |
| GLB105-21 | 105 | 15.1 | 21 | 950 | |
| GLB105-27 | 105 | 15.1 | 27 | 1,200 | |
| GLB105-40 | 105 | 15.1 | 40 | 1,800 | |
| GLB105-50 | 105 | 15.1 | 50 | 2,250 | |
| GLB120-21 | 120 | 17.3 | 21 | 950 | |
| GLB120-27 | 120 | 17.3 | 27 | 1,200 | |
| GLB120-36 | 120 | 17.3 | 36 | 1,600 | |
| GLB120-40 | 120 | 17.3 | 40 | 1,800 | |
| GLB170-21 | 170 | 24.5 | 21 | 950 | |
| GLB170-27 | 170 | 24.5 | 27 | 1,200 | |
| GLB170-36 | 170 | 24.5 | 36 | 1,600 | |
| GLB170-40 | 170 | 24.5 | 40 | 1,800 | |
| GLB190-21 | 190 | 27.4 | 21 | 950 | |
| GLB190-27 | 190 | 27.4 | 27 | 1,200 | |
| GLB190-33 | 190 | 27.4 | 33 | 1,500 | |
| GLB190-40 | 190 | 27.4 | 40 | 1,800 | |
| GLB230-21 | 230 | 33.1 | 21 | 950 | |
| GLB230-27 | 230 | 33.1 | 27 | 1,200 | |
| GLB230-33 | 230 | 33.1 | 33 | 1,500 | |
| GLB230-40 | 230 | 33.1 | 40 | 1,800 | |
| GLB300-21 | 300 | 43.2 | 21 | 950 | |
| GLB300-27 | 300 | 43.2 | 27 | 1,200 | |
| GLB300-33 | 300 | 43.2 | 33 | 1,500 | |
| GLB410-21 | 410 | 59 | 21 | 950 | |
| GLB410-27 | 410 | 59 | 27 | 1,200 | |
| GLB410-33 | 410 | 59 | 33 | 1,500 | |
| GLB410-40 | 410 | 59 | 40 | 1,800 | |
| GLB521-21520 ml/rev in source; model name pending review | 520 | 75 | 21 | 950 | |
| GLB521-27520 ml/rev in source; model name pending review | 520 | 75 | 27 | 1,200 | |
| GLB521-33520 ml/rev in source; model name pending review | 520 | 75 | 33 | 1,500 | |
| GLB521-40520 ml/rev in source; model name pending review | 520 | 75 | 40 | 1,800 | |
| GLB625-21 | 625 | 90 | 21 | 950 | |
| GLB625-27 | 625 | 90 | 27 | 1,200 | |
| GLB625-33 | 625 | 90 | 33 | 1,500 | |
| GLB700-21 | 700 | 100.8 | 21 | 950 | |
| GLB700-27 | 700 | 100.8 | 27 | 1,200 | |
| GLB700-33 | 700 | 100.8 | 33 | 1,500 | |
| GLB800-14 | 800 | 115.2 | 14 | 650 | |
| GLB800-20 | 800 | 115.2 | 20 | 900 | |
| GLB800-27 | 800 | 115.2 | 27 | 1,200 | |
| GLB1000-14 | 1000 | 144 | 14 | 650 | |
| GLB1000-20 | 1000 | 144 | 20 | 900 | |
| GLB1000-27 | 1000 | 144 | 27 | 1,200 | |
| GLB1100-14 | 1100 | 158.4 | 14 | 650 | |
| GLB1100-18 | 1100 | 158.4 | 18 | 800 | |
| GLB1100-21 | 1100 | 158.4 | 21 | 950 | |
| GLB1400-14 | 1400 | 201.6 | 14 | 650 | |
| GLB1400-18 | 1400 | 201.6 | 18 | 800 |
¹ Source normalization is shown as m³/d·100r. These are brochure reference figures, not a prediction of actual production.
² Water-column head is not well depth. Fluid, speed, wear and system constraints require engineering review.
BEFORE CONFIRMING A CONFIGURATION
Reference data is a starting point.
Reference flow at 100 rpm is not actual daily production. Water-column head is not well depth. GLB521 is printed with 520 ml/rev in the source; that discrepancy remains open for technical clarification.